<link rel="stylesheet" href="styles.f3b1fba60ec7970c.css">

Detection of multiple power quality disturbance events for micro-smart grids with hydrogen fuel cell

dc.authorid0000-0003-0062-3817
dc.authorid0000-0001-7243-7939
dc.authorid0000-0002-3257-7838
dc.contributor.authorAkkaya, Sitki
dc.contributor.authorGucyetmez, Mehmet
dc.contributor.authorUyar, Murat
dc.contributor.authorHayber, Sekip Esat
dc.date.accessioned2026-03-14T11:48:44Z
dc.date.available2026-03-14T11:48:44Z
dc.date.issued2025
dc.departmentSiirt Üniversitesi
dc.description.abstractDue to some factors such as a greater need for energy and diversification of energy sources, micro-smart grids (MSGs) with hydrogen energy (HE) based fuel cells (FCs) are becoming increasingly widespread, and these systems have effects on the power grid in terms of power quality. Single and multiple power quality disturbances (PQDs) and their levels originating from the interaction and effects of peripheral units with FC-MSG should be detected using signal processing methods. The study aims to determine the error metrics of these disturbances when multiple disturbances occur in the power system with FC-MG, to analyze whether they are FC-induced, with which signal processing methods they can be analyzed, whether a filter is needed, and to determine the effectiveness of signal processing methods for different PQD situations. In the signal processing stage, wavelet synchro-squeezed transform (WSST) is used to analyze and visualize the PQD signals. Additionally, the time-frequency representation derived by WSST is compared with that derived from the continuous wavelet transform (CWT) to evaluate its ability to visually decompose the time-varying frequency components of PQD signals. Statistical error metrics, the root mean square error (RMSE), mean square error (MSE), and correlation (Corr) values, are used to evaluate the accuracy of the results. Specifically, RMSE, MSE, and Corr improved by 7.38%, 1.04%, and 47.33%, respectively, for the four mixed disturbance signals. The results show that the proposed visual analysis tool effectively detects multiple PQD signals. Determining the type and time of the disturbance performed in this study ensures timely and correct switching of relays in FC-MSG systems. Thus, MSG and FCs are less impacted by disturbance.
dc.description.sponsorshipSivas University of Science and Technology, Department of Electrical-Electronics Engineering, Smart Grids Laboratory
dc.description.sponsorshipThe authors would like to thank the Sivas University of Science and Technology, Department of Electrical-Electronics Engineering, Smart Grids Laboratory.
dc.identifier.doi10.1016/j.ijhydene.2025.02.046
dc.identifier.endpage563
dc.identifier.issn0360-3199
dc.identifier.issn1879-3487
dc.identifier.startpage548
dc.identifier.urihttps://doi.org/10.1016/j.ijhydene.2025.02.046
dc.identifier.urihttps://hdl.handle.net/20.500.12604/8945
dc.identifier.volume144
dc.identifier.wosWOS:001518660400001
dc.identifier.wosqualityQ1
dc.indekslendigikaynakWeb of Science
dc.language.isoen
dc.publisherPergamon-Elsevier Science Ltd
dc.relation.ispartofInternational Journal of Hydrogen Energy
dc.relation.publicationcategoryMakale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanı
dc.rightsinfo:eu-repo/semantics/closedAccess
dc.snmzKA_WoS_20260310
dc.subjectFuel Cell
dc.subjectHydrogen Energy
dc.subjectMicro-Smart Grids
dc.subjectPower Quality
dc.subjectMultiple Disturbances
dc.titleDetection of multiple power quality disturbance events for micro-smart grids with hydrogen fuel cell
dc.typeArticle

Dosyalar