dc.description.abstractIn recent years, with the depletion of energy resources, studies on the use of renewable and clean energy sources have increased rapidly. The use of renewable energy sources is particularly prominent in the construction sector, which has a high energy consumption. This study examines the energy performance of Building-Integrated Photovoltaic (BIPV) systems applied to different fa & ccedil;ade designs in a prototype office building in the Mediterranean climate, specifically designed for renewable energy use in buildings. Four different PV fa & ccedil;ade design scenarios were determined for the prototype building, and energy performance analyses were conducted using the DesignBuilder simulation program. In this context, energy performance values such as Energy Coverage Ratio (ECR) and Self-Consumption Ratio (SCR) of the scenarios were compared. As a result of the comparison, the S2 inclined PV fa & ccedil;ade demonstrated the highest ECR (42.92%) and the lowest SCR (70.9%). The findings show that facade designs and the application of PV systems are important elements in determining the building energy performance and can meet a significant portion of the energy consumption. The study contributes to the evaluation of energy performance arising from differences in PV system applications in fa & ccedil;ade designs during the building's preliminary design process.
dc.identifier.doi10.47480/isibted.1727690
dc.identifier.endpage65
dc.identifier.issn1300-3615
dc.identifier.issue1
dc.identifier.orcid0000-0001-7446-4711
dc.identifier.scopus2-s2.0-105040070475
dc.identifier.scopusqualityQ4
dc.identifier.startpage52
dc.identifier.urihttps://doi.org/10.47480/isibted.1727690
dc.identifier.urihttps://hdl.handle.net/20.500.12604/11992
dc.identifier.volume46
dc.identifier.wosWOS:001771917200004
dc.identifier.wosqualityQ4
dc.indekslendigikaynakWeb of Science
dc.indekslendigikaynakScopus
dc.language.isoen
dc.publisherTurkish Soc Thermal Sciences Technology
dc.relation.ispartofIsi Bilimi ve Teknigi Dergisi-Journal of Thermal Science and Technology
dc.relation.publicationcategoryMakale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanı
dc.rightsinfo:eu-repo/semantics/openAccess
dc.snmzKA_WOS_20261017
dc.subjectBipv
dc.subjectOffice Building
dc.subjectFacade Design
dc.subjectBuilding Envelope
dc.subjectEnergy Performance
dc.titleDesign and Performance Assessment of Photovoltaic Building Envelopes for a Prototype Office Building in the Mediterranean
dc.typeArticle

Dosyalar