<link rel="stylesheet" href="styles.f3b1fba60ec7970c.css">

Graphene oxide-perylene derivative nanocomposite thin films on ITO for amperometric NADH sensing

dc.contributor.authorKiransan, Kader Dagci
dc.contributor.authorGultekin, Demet Demirci
dc.contributor.authorAksu, Zeris
dc.contributor.authorArik, Mustafa
dc.contributor.authorAlanyalioglu, Murat
dc.date.accessioned2026-10-23T18:13:57Z
dc.date.available2026-10-23T18:13:57Z
dc.date.issued2026
dc.departmentSiirt Üniversitesi
dc.description.abstractPerylene derivative dyes (PDDs) have attracted considerable attention in optoelectronic and sensing applications due to their highly conjugated structures and remarkable fluorescence properties, enabling efficient redox mediation. In this study, two novel PDDs (P-12 and P-13) were synthesized and reported for the first time. Together with three previously reported derivatives, these compounds were used to prepare nanocomposites with graphene oxide (GO) via ultrasonic mixing. The resulting GO/PDD nanocomposites were subsequently drop-cast onto indium tin oxide-coated glass (ITO) to fabricate GO/PDD/ITO electrodes for amperometric detection of nicotinamide adenine dinucleotide (NADH). Comprehensive characterization using UV-Vis spectroscopy, SEM, FTIR, Raman, XPS, and XRD confirmed the successful integration of PDD molecules onto GO sheets and the formation of stable thin films. Electrochemical studies revealed that the GO/P-5/ITO electrode exhibited the highest electrocatalytic activity toward NADH oxidation, attributed to enhanced electron transfer mediated by PDD molecules within the otherwise poorly conductive GO matrix. Under optimized conditions, the sensor showed a linear response over the range of 10.9-800 & micro;M, with a limit of detection of 3.3 & micro;M and a sensitivity of 0.30 & micro;A & micro;M-1 cm-2. The sensor exhibited satisfactory recoveries in isotonic serum, whereas matrix-dependent signal suppression was observed in complex samples such as energy drink and milk due to interfering electroactive species. These findings indicate that the developed platform is more suitable for low-interference biological media. These results highlight that GO/PDD/ITO electrodes provide a promising platform for efficient NADH sensing.
dc.description.sponsorshipScientific and Technological Research Council of Turkiye [221Z308] -- This study was supported by the Scientific and Technological Research Council of Turkiye (TUBI center dot TAK) under project no: 221Z308. The authors thank to Prof. Dr. O & uml; zgur Altan Bozdemir for his intellectual support regarding the synthesis of perylene derivatives.
dc.identifier.doi10.1016/j.synthmet.2026.118215
dc.identifier.issn0379-6779
dc.identifier.scopus2-s2.0-105042427585
dc.identifier.scopusqualityQ1
dc.identifier.urihttps://doi.org/10.1016/j.synthmet.2026.118215
dc.identifier.urihttps://hdl.handle.net/20.500.12604/12210
dc.identifier.volume320
dc.identifier.wosWOS:001805299600001
dc.identifier.wosqualityQ2
dc.indekslendigikaynakWeb of Science
dc.indekslendigikaynakScopus
dc.language.isoen
dc.publisherElsevier Science Sa
dc.relation.ispartofSynthetic Metals
dc.relation.publicationcategoryMakale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanı
dc.rightsinfo:eu-repo/semantics/closedAccess
dc.snmzKA_WOS_20261017
dc.subjectAmperometric Sensor
dc.subjectNadh
dc.subjectPerylene Derivative Dyes
dc.subjectGraphene Oxide
dc.subjectIto
dc.titleGraphene oxide-perylene derivative nanocomposite thin films on ITO for amperometric NADH sensing
dc.typeArticle

Dosyalar