<link rel="stylesheet" href="styles.f3b1fba60ec7970c.css">

Test-retest and inter-rater reliability of the incremental shuttle walk test in healthy university students

dc.contributor.authorAcar, Yasemin
dc.contributor.authorTikac, Gulsum
dc.date.accessioned2026-10-23T18:14:10Z
dc.date.available2026-10-23T18:14:10Z
dc.date.issued2026
dc.departmentSiirt Üniversitesi
dc.description.abstractBackground Although the Incremental Shuttle Walk Test (ISWT) is commonly used in clinical and research settings, data on its reliability and measurement error indices remain insufficient. Aims To investigate the test-retest and inter-rater reliability of the ISWT in healthy university students and to establish reference values for measurement error indices. Methods Forty-nine participants were recruited, of whom 45 completed all testing procedures. Each participant performed four ISWTs-two administered by Rater 1 and two by Rater 2-across two sessions conducted 2-7 days apart. Test-retest and inter-rater reliability were assessed using intraclass correlation coefficients (ICC), standard error of measurement (SEM), minimal detectable change at the 95% confidence level (MDC95), and Bland-Altman analyses. Results The mean ISWT distance was 638.44 +/- 103.50 m and 646.67 +/- 109.44 m for Rater 1 across sessions (p=0.255), and 621.11 +/- 123.33 m and 654.00 +/- 142.53 m for Rater 2 (p < 0.001). Test-retest reliability was good to excellent, with ICCs of 0.899 for Rater 1 and 0.873 for Rater 2. Corresponding SEM and MDC95 values were 33.83 m/93.71 m and 47.43 m/131.39 m, respectively. Inter-rater reliability was also good to excellent, with ICCs of 0.869 in Session 1 and 0.899 in Session 2. Bland-Altman analyses confirmed acceptable agreement. Conclusions The ISWT demonstrated good to excellent test-retest and inter-rater reliability, providing novel reference values for measurement error indices. These findings support its use as a reliable tool for assessing functional exercise capacity in both clinical and research settings.
dc.description.sponsorshipSiirt University -- Open access funding provided by the Scientific and Technological Research Council of Turkiye (TUB & Idot;TAK).
dc.identifier.doi10.1007/s11845-026-04406-y
dc.identifier.endpage2482
dc.identifier.issn0021-1265
dc.identifier.issn1863-4362
dc.identifier.issue4
dc.identifier.orcid0000-0001-7375-6747
dc.identifier.pmid41999519
dc.identifier.scopus2-s2.0-105035849503
dc.identifier.scopusqualityQ1
dc.identifier.startpage2473
dc.identifier.urihttps://doi.org/10.1007/s11845-026-04406-y
dc.identifier.urihttps://hdl.handle.net/20.500.12604/12294
dc.identifier.volume195
dc.identifier.wosWOS:001743443400001
dc.identifier.wosqualityQ2
dc.indekslendigikaynakWeb of Science
dc.indekslendigikaynakScopus
dc.indekslendigikaynakPubMed
dc.language.isoen
dc.publisherSpringer London Ltd
dc.relation.ispartofIrish Journal of Medical Science
dc.relation.publicationcategoryMakale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanı
dc.rightsinfo:eu-repo/semantics/openAccess
dc.snmzKA_WOS_20261017
dc.subjectIncremental Shuttle Walk Test
dc.subjectTest-Retest Reliability
dc.subjectInter-Rater Reliability
dc.subjectFunctional Exercise Capacity
dc.subjectUniversity Students
dc.titleTest-retest and inter-rater reliability of the incremental shuttle walk test in healthy university students
dc.typeArticle